portfolio-banner-image

CORE COLOUR

  • As per IS: 694:2010 - 2 CORE - Red, Black / 3 CORE - Red, Yellow, Blue / 4 CORE - Red, Yellow, Blue, Black
  • As per IEC:60227 - 3 CORE - Blue, Brown, Black or Yellow/ Green / 4 CORE -Blue, Brown, Black, Grey or Yellow/Green

COPPER

  • EC flexible copper generally conforms to IEC 60228, DIN VDE 0295, IS 8131

INSULATION:

  • Special grade of Rubber EPR, EPDM for inner & outer.

TECHNICAL DATA

  • WORKING TEMPERATURE : -20° C to + 70° C
  • VOLTAGE RANGE : UP TO 1100 V
  • TEST VOLTAGE : 3000 V
  • MINIMUM BENDING : 6 X cable diameter

APPLICATION

  • Drinking Water Supply Pumps, Irrigation of water, appliances, control panels, machinery, and industries of every nature.

SPECIAL FEATURES:

  • Excellent Impact Resistant
  • Excellent Weather Resistant

PACKING

  • 500/1000 meters on drums.
Conductor Insulation TotalThichness of double Sheath and Diameter Conductor Resistance at 20° C (Max) Currant Rating at 40° C
Size of Cable No. of Wire/Size of wire Thickness Core OD Sheath Thickness(Nominal) 3 Core Outer Diameter 4 Core Outer Diameter
Sq. mm Nos. mm mm mm mm mm mm /km. Amps.
1.5 22/0.30 0.60 2.90 1.20 9.50 10.30 12.1 14
2.5 36/0.30 0.70 3.50 1.4 11.50 13.0 7.41 18
4.0 56/0.30 0.80 4.00 1.40 14.0 14.80 4.95 26
6.0 84/0.30 0.80 5.0 1.60 15.50 16.0 3.30 31
10.0 140/0.30 1.0 6.0 2.0 19.0 20.20 1.91 42
16.0 224/0.30 1.0 7.30 2.0 21.50 23.50 1.21 57
25.0 350/0.30 1.20 9.50 2.30 26.0 28.0 0.780 72
35.0 490/0.30 1.2 11.0 2.50 29.0 31.50 0.554 90